mikelasas.blogg.se

Power sweep bruker epr
Power sweep bruker epr





power sweep bruker epr

Modulation Reference: 10Vpp rectangular input impedance: 50 Ohm, Receiver gain dynamic: 0- 106dB, Gain step size: 1dB, Time constant: 0.01ms-5.24s, ADC Type: integrating, ADC Conversion: 0.16ms- 5.24s per point, ADC Resolution: constant 22 bits automatic calibration of phase and amplitude for any frequency in the specified frequency range, external Trigger capability, Setup Scan futemal Data Buffer E27L Low frequency channel, 1kHz to 6kHz in 0.1 kHz steps, quadrature detection: two channels, multiple modulation (two or more signal channels in series).Į32 Precision Microprocessor Hall Field Controller, -50 G to +23 kG operating range, field accuracy typically better than +/-500 mG over full range, center field setting in 50 mG steps, sweep width setting in 100 mG steps, 12 bit parallel sweep input and output, internal and external address advance, InterfaceĮ48MBC Microwave bridge controller for attenuation-, reference phase-, bias-, microwave frequency setting, setup scan with real-time display, sweep width variable up to 50G, manual or automated tuning, manual or automated matching, cavity Q-value display, microwave power display mode picture zoom functionĮ49X SuperX High Power Microwave Bridge, 600 mW low noise Gunn microwave source, AFC stability 10, microwave power leveler, 200 mW leveled output up to 60 dB attenuation in 1 dB steps, power meter with digital display in unleveled and leveled mode, +/-0.2 dB attenuation precision, automatic AFC gain control, 6 MHz AFC dynamic range, up to 80 MHz tuning range, ultra-low noise Signal Detection, low noise preamplifier 30 Hz to 6.5 MHz, microwave frequency output port for frequency meter or FF-lock matched reference arm with variable attenuation and phase setting delay line, iris motor tuning,Į41 FC X band digital frequency counter with RS 232 interface, 1 GHz to 10 GHzĮ532M Data Acquisition System mainframe unit console with VME- Bus slots, power supply for VME bus configuration and+/- 15 V linear power supply for the analog electronicsĮ50 CPU (32 bit data bus, 32 bit address bus), VME- bus interface with arbiter and interrupt controller, on board dual ported memory, Ethernet controllerĮ 532 GIS General purpose spectrometer interface RS 232 C, Centronics, IEC 625, SLD-Bus, 3 programmable pulse outputs, 2 Interrupt request lines,Į532ADF High speed digitizer, two channels, 100 ns aperture time, 2 MHz sampling rate, hardware accumulator with 8 K x 32 bit on board memory,Į 532 RSC Digital rapid scan controller, up to 200G sweep width, sweep time range and digital acquisition: 500 us to 303 s modulation generator 61 Hz to 100 kHzĮ 532 TVI Ethernet hub connecting all spectrometer devicesĮ 5000LX LINUX Workstation Pentium N 3000 MHz 512MB Memory 80 GB Hard disk 2 Ethernet Interfaces 3 Yz" Floppy drive CD Drive R/W DVDROM E 532 OS OS9 Operating system installation package E 500-10/12 Research grade Electron-Paramagnetic Resonance CW Spectrometer System ELEXSYS-Series with 10" Magnet and 12 kW power supplyĮ 513 S E 500 Single door console including console power supply, full console wiring and safety circuits,Į 27 Signal Master base station with E 527H high frequency unit including modulation power amplifier (up to four signal channels can be accommodated), InterfaceĮ27H High frequency Signal Channel Module, 6kHz to 100 kHz, settable in 1 kHz steps, first and second harmonic, phase resolution 0.10, phase stability : 0.1 degree lCxh, modulation output: 1mVpp-10Vpp







Power sweep bruker epr